


Any defects should be reported and remediated as soon as possible. All luminaires should remain lit throughout this period. When doing so, the primary lighting circuit must be switched off and emergency lights left on for three hours in line with BS 5266-1. A record of all monthly tests must be kept, including any faults which should be reported to the responsible person to ensure that appropriate remedial action can be taken.įor the annual test, the requirements for emergency lighting are to test for a duration of three hours.

The fish key should be used rather than switching off the mains lighting power, which may be hazardous to other occupants. The test should be done using the secure device key, commonly called a fish key due to its shape. Luminaires should be free from damage and clean. The monthly emergency lighting tests, also known as the ‘flick tests’, are a short functional test simulating failure of the mains power supply which ensures the lamp switches on and illuminates correctly. maintained emergency lighting or non-maintained), but as a general guide, you should aim to get your emergency lighting system tested monthly, in addition to an annual ‘full duration’ test as described in BS 5266-1. The frequency in which you should get your emergency lighting tested can vary depending on system type (i.e. How often should emergency lighting be tested?įirst and foremost, your emergency lighting must be tested by a competent person due to the important nature of the system in ensuring occupant safety in the event of an emergency. (Standby lighting which is designed to support ongoing activities in the event of a power failure is not a legal requirement).ĭue to emergency light systems being so important in the process of protecting building occupants and highlighting escape routes and firefighting equipment, it is essential that emergency escape lighting is regularly tested and maintained to ensure that in the event of a failure of mains power, the lighting works correctly and escape routes are effectively illuminated (escape route lighting).This advice and guidance article provides advice on how often you should get your emergency lighting tested, and how to test your emergency lighting. In the UK, is a legal requirement under both Building Regulations and the Regulatory Reform (Fire Safety) Order 2005, that all business premises including offices, factories, pubs and clubs, schools, hospitals and entertainment venues – including tents and marquees – are provided with emergency escape lighting. BS 5266-1 states that a building must have adequate illumination to support escape and identify firefighting equipment (or any other fire safety equipment). Emergency lighting is required in premises to enable occupants to escape safely in an emergency situation.
